Available 24/7 for emergency repairs
Synergy Gas & Plumbing logo Synergy Gas & PlumbingGas Safe Registered
24 hour emergency call-out 07413 385767 Answered 7 days a week, day or night
Case study · Carbon monoxide · Bordesley Green

Bordesley Green: a carbon monoxide alarm going off, and kitchen foil around the gas hob burners blocking the air they need

We were called to Bordesley Green because the customer's carbon monoxide alarm had been going off. The cause was on the gas hob: it had been covered with foil, and the foil was blocking the ports that let in the primary air the burners need to burn cleanly. We tested the hob and the room, and advised the customer to keep the foil off.

In short

We were called to Bordesley Green because the customer's carbon monoxide alarm had been going off. We found the reason on the gas hob: it had been covered with foil, and the foil was blocking the ports that let the primary air into the burners. Without enough air, a gas burner cannot burn cleanly. With the foil removed, we tested the hob with our analyser and took carbon monoxide readings in the room. The readings were acceptable and the hob was left in use. We advised the customer to keep the foil off.

Request an engineer

Four details and we will get back to you to arrange a time. Prefer to talk? Call 07413 385767.

Gas trace and repair: £99 for the first hour in office hours. Pipework repairs are quoted on site before we carry on.

No travel charge within 10 miles of B20 2JS. Further out, £2 per mile may apply — always agreed before anything is booked. Full price list

The first part, such as B20, is enough.
Add email, boiler make or a preferred time (optional)

Photos help: you can send them on WhatsApp once your enquiry is in.

Sending this is an enquiry, not a booked appointment: we confirm a time with you first. We only use your details to reply. Privacy notice

Or book online for a morning or afternoon arrival window, or WhatsApp us a photo

  • CO alarmHad been going off
  • Foil on the hobBlocking the burners’ primary air
  • TestedHob analyser and room CO readings acceptable

The call-out

We were called to Bordesley Green because the customer's carbon monoxide alarm had been going off.

What we found

The gas hob had been covered with foil, as you can see in the photos. The foil was tucked in around the burners and was blocking the ports that let in the primary air: the air a gas burner mixes with the gas before it burns. A burner that cannot get enough air burns incompletely, and that produces carbon monoxide.

What we checked

With the foil removed, we tested the hob with our flue gas analyser and took carbon monoxide readings in the room. The readings were acceptable, and the hob was left in use. We advised the customer to keep the foil off the hob.

Removing the foil is not the end of it

Do not assume that taking the foil off has solved the problem without the right checks. On a call-out like this, a Gas Safe engineer checks:

  • that the room and the appliance have adequate ventilation;
  • for any sign of flame impingement or sooting;
  • that the gas type, the injectors and the operating pressure are correct for the appliance;
  • the manufacturer's instructions and the appliance's combustion performance;
  • ambient carbon monoxide readings, taken with a suitable calibrated instrument and following the relevant safe testing procedure.

Our carbon monoxide guide lists the symptoms, and the signs to look for on your appliances.

If your alarm goes off

Get everyone into fresh air, leave doors and windows open, and call the National Gas Emergency Service on 0800 111 999. If anyone feels unwell, call NHS 111, or 999 if they have collapsed or are struggling to breathe. Do not use the appliance again until it has been checked.

What it costs

In office hours (Mon–Fri 8am–5pm) an emergency callout is £99 for diagnosis and the first hour. Outside office hours we quote by phone before we set off. Details are on our price list.

Common questions

What should I do if my carbon monoxide alarm goes off?

Get everyone outside into fresh air, leave doors and windows open, and call the National Gas Emergency Service on 0800 111 999. If anyone feels unwell, call NHS 111 or, if they have collapsed or are struggling to breathe, 999. Do not use the appliance again until a Gas Safe engineer has checked it.

Can foil on a gas hob cause carbon monoxide?

It can. A gas burner draws in primary air through ports around its base and mixes it with the gas before it burns. Foil tucked around the burners can block those ports, and a burner short of air burns incompletely, which produces carbon monoxide. That is what we found here.

Is it safe once the foil is removed?

Do not assume so. Removing the foil takes away the cause, but the hob still needs checking by a Gas Safe engineer, including combustion and carbon monoxide readings. On this job the readings with the foil off were acceptable and the hob was left in use.

How much does a call-out cost?

In office hours (Mon–Fri 8am–5pm) an emergency callout is £99 for diagnosis and the first hour. Outside office hours we quote by phone before we set off.

Job attended and photographed by our engineers, November 2026. Written up by Saeed Iqbal, the engineer who leads Synergy Gas & Plumbing (Gas Safe registered 594385). More of our work in the city is on our Birmingham page, and every job we write up is on the case studies index.

What it costs

Updated Sept 2026

£99 in office hours

Emergency callout in office hours (Mon–Fri 8am–5pm): £99 for diagnosis and the first hour. Outside office hours we quote by phone before we set off.

No travel charge within 10 miles of B20 2JS. Further out, £2 per mile may apply — always agreed before anything is booked.

Full price list

This job

Bordesley Green · November 2026
Call-outCarbon monoxide alarm going off
FoundFoil over the gas hob, blocking the burners' primary air ports
CheckedHob tested with the analyser; room CO readings taken
ResultReadings acceptable with the foil off; hob left in use; customer advised
More jobs

Other recent work

Carbon monoxide alarm going off?

Get everyone into fresh air and call the National Gas Emergency Service on 0800 111 999 first. Once everyone is safe, call us to have the appliance checked before it is used again.