Case study · Boiler service · Solihull

Solihull: a service visit to a Vaillant ecoTEC pro 28 that was leaking, with the heating staying on with no demand, and a corroded diverter valve replaced

We were there for an annual service, and the customer mentioned the boiler was leaking and the heating was staying on with nothing asking for it. The diverter valve had rust and corrosion around its ports, so we replaced it.

In short

We visited a Vaillant ecoTEC pro 28 combi in Solihull for its annual service, and the customer mentioned two problems: the boiler was leaking, and the heating was staying on even when nothing was asking for heat. With the case off, the diverter valve, the valve that switches the boiler between heating and hot water, had rust and corrosion around its ports, and there was rust staining in the base of the case below it. A diverter valve in that state accounts for both problems, so we replaced it with a new one. We checked the expansion vessel charge and finished with a flue gas analysis: a CO/CO2 ratio of 0.0005, comfortably inside the limit.

Request a boiler service

Four details and we will get back to you to arrange a time. Prefer to talk? Call 07413 385767.

Basic service £95, intermediate £125, full strip-down £185.

No travel charge within 10 miles of B20 2JS. Further out, £2 per mile may apply — always agreed before anything is booked. Full price list

The first part, such as B20, is enough.
Add email, boiler make or a preferred time (optional)

Photos help: you can send them on WhatsApp once your enquiry is in.

Sending this is an enquiry, not a booked appointment: we confirm a time with you first. We only use your details to reply. Privacy notice

Or WhatsApp us a photo · book a confirmed time online

  • ReportedLeaking, heating on with no demand
  • 1 partCorroded diverter valve replaced
  • 0.0005CO/CO2 ratio on the analyser

The visit

We visited a Vaillant ecoTEC pro 28 combi in Solihull for its annual service. When we arrived, the customer mentioned two problems: the boiler was leaking, and the heating was staying on even when nothing was asking for heat. A service is a set of checks on the boiler and its safety, and it is also the best time to look into anything the customer has noticed.

What we found

With the case off and the control box lowered, there was rust staining in the base of the case. The diverter valve, the valve that switches the boiler between heating and hot water, had rust and corrosion around its ports. You can see it out of the boiler in the third photo.

That accounts for both problems. The diverter valve is what decides whether the boiler's heat goes to the radiators or to the hot water. Corroded seals at its ports let water out, and a valve that is sticking in the heating position keeps sending heat round the radiators even when the thermostat is not asking for it.

The fix

We replaced the diverter valve with a new one, in the fourth photo, and put the hydraulics back together. We checked the expansion vessel charge with a pump gauge, which read 1.00 bar, and finished with a flue gas analysis: CO 44 ppm, CO2 8.9% and a CO/CO2 ratio of 0.0005, comfortably inside the limit.

Our boiler servicing page explains what each level of service includes. We also serviced another Vaillant ecoTEC pro 28 in Kitts Green, where checking the flue turned up a problem in the loft.

What it costs

A basic annual service is £95, intermediate £125 and a full strip-down £185. Parts found worn during a service, like a diverter valve, are quoted before we fit them. Details are on our price list.

Common questions

What does the diverter valve do on a combi boiler?

It switches the hot water from the boiler between the heating circuit and the hot water heat exchanger. When you turn on a hot tap it sends the heat to your hot water; the rest of the time it sends it round the radiators. When one sticks or fails you can lose heating, hot water, or both.

Why does my heating stay on when nothing is asking for it?

On a combi boiler a common cause is a diverter valve sticking in the heating position, which is what we found here. A faulty room thermostat, timer or wiring can do the same. It is worth getting checked, because it wastes gas and can mean the hot water side is not working properly either.

Why replace a part during a service?

A service is the time to find wear before it becomes a breakdown. If we find a part in poor condition we show you and quote before fitting anything. Doing it on the same visit saves a second callout later, often in the middle of winter.

What does the flue gas analysis show?

It measures what the boiler is burning and putting out of the flue, including carbon monoxide and carbon dioxide. The CO/CO2 ratio tells us how cleanly it is burning. Here it read 0.0005, comfortably inside the limit.

How often should a Vaillant boiler be serviced?

Once a year. Vaillant needs an annual service to keep the warranty valid, and it is the only way to catch problems like this one early.

Job attended and photographed by our engineers, October 2026. Written up by Saeed Iqbal, the engineer who leads Synergy Gas & Plumbing (Gas Safe registered 594385). More of our work in the area is on our Solihull page, and every job we write up is on the case studies index.

What it costs

Updated Sept 2026

From £95

Basic service £95, intermediate £125, full strip-down £185.

No travel charge within 10 miles of B20 2JS. Further out, £2 per mile may apply — always agreed before anything is booked.

Full price list

This job

Solihull · October 2026
JobAnnual boiler service
ReportedLeaking; heating on with no demand
BoilerVaillant ecoTEC pro 28 combi
FoundDiverter valve corroded around its ports
FixNew diverter valve fitted
CheckedExpansion vessel 1.00 bar; CO/CO2 0.0005