Case study · Boiler repair · Solihull
A leaking manifold on a Worcester Greenstar 28i Junior in Solihull: diagnosed, part sourced, collected and fitted the same day
The right-hand manifold inside the boiler was leaking. Rather than book a return visit, we found the part locally, fetched it and fitted it before the day was out.
A Worcester Greenstar 28i Junior in Solihull was leaking from inside the case. We traced it to the right-hand hydraulic manifold, the plastic block that carries water between the pump, the heat exchanger and the pipework. It had corroded and was weeping at the joints. A manifold is not a part we carry, but rather than book a second visit we found one at a local supplier the same day, collected it, fitted it and tested the boiler back into service. The customer was extremely happy with the service.
Boiler leaking or losing pressure?
Leave a number and a postcode and we will ring you back — usually within the hour during office hours. If it is dripping onto electrics, turn it off and ring instead.
1 dayDiagnosed, sourced, collected, fitted
1 partRight-hand manifold, like for like
0Return visits needed
The boilerThe Greenstar 28i Junior with the case off: fan, flue and heat exchanger above, pump and hydraulics below.Where it was leakingThe lower hydraulics with the pump and the right-hand manifold. Scale and corrosion around the joints marked the leak.The causeThe old manifold out. Corrosion and limescale around every joint on the block, and no sensible way to seal it.The fixNew manifold in, pump and pipework reconnected, and the boiler refilled and tested dry.
The call
The customer in Solihull had a Worcester Greenstar 28i Junior that was leaking from inside the case. A boiler leaking internally is one to act on quickly: the water finds its way onto the electrics and the control board, and a small leak turns into a big bill.
What we found
With the case off we traced the leak to the right-hand hydraulic manifold. On this boiler the manifolds are the plastic blocks at the bottom that carry water between the pump, the plate heat exchanger and the pipework, and they hold the sensors and valves that the boiler relies on. This one had corroded and scaled up at its joints and was weeping. You can see the state of it in the photos above. A manifold in that condition cannot be resealed; it needs replacing.
The fix
A manifold is specific to the boiler and not something we carry on the van. The usual route is to order it and come back, which means a second visit and a customer with a leaking boiler in the meantime. Instead we rang round, found the right manifold at a local supplier that afternoon, went and collected it, and came back to fit it. The old manifold came out, the new one went in, the pump and pipework were reconnected, and the boiler was refilled, run and checked dry at every joint before we left.
Diagnosed, sourced, collected and fitted in a day. The customer was extremely happy with the service, and that is the outcome we want on every repair where the part is within reach.
Why we do the parts run
Most of what fails on a boiler is on the van. When it is not, the difference between a good repair and a frustrating one is often whether the engineer is willing to go and get the part. Where a supplier within reach has it in stock, we will collect it the same day rather than leave you waiting on a delivery. It is a big part of why 88% of our repairs are finished on the first day, and it is why we ask you for the make and model when you book, so we can check parts availability before we set off.
What it costs
A boiler repair callout is £99, covering attendance, diagnosis and the first hour. Parts are quoted before we fetch or fit them, and a same-day parts run is part of the service rather than a premium. Full details are on our boiler repair page, and if your boiler is losing pressure without an obvious leak, read our boiler checklist first: an internal leak like this one is a common cause.
Common questions
What is the manifold on a Worcester Greenstar Junior?
The hydraulic manifolds are the plastic blocks at the bottom of the boiler that route water between the pump, the plate heat exchanger and the flow and return. They carry the diverter valve, sensors and the pressure relief valve. When one corrodes or cracks it leaks inside the case, and because it holds so many other parts it is replaced as a block rather than patched.
Can you get boiler parts the same day?
Often, yes. For the common makes there are trade suppliers across Birmingham and the Black Country, and if one has the part in stock we will collect it that day rather than order it and come back. Tell us the make and model when you book and we will check before we arrive. Where a part has to come from the manufacturer, we say so up front.
Is an internal boiler leak an emergency?
It is urgent. Water inside a boiler runs onto the fan, the gas valve and the control board, and a leak that would have been a cheap part can take the electronics with it. If you see water under or inside the boiler, or the pressure keeps dropping, turn it off and call us the same day.
Do you cover Solihull?
Yes, the whole borough: Shirley, Olton, the town centre, Knowle, Dorridge and Monkspath, from our Handsworth Wood base. We hold same-day slots for no heating and no hot water, and a leaking boiler goes into one of those.
Job attended and photographed by our engineers in Solihull, April 2026. Written up by Saeed Iqbal, the engineer who leads Synergy Gas & Plumbing (Gas Safe registered 594385). More recent jobs in the area are on our Solihull page, and every job we write up is on the case studies index.
Get a price
Four taps for a fixed figure.
What do you need?
What sort of job is it?
Here is the price range
Call us — do not wait on a form
07413 385767
Answered 24 hours. If you can smell gas, first call the National Gas Emergency Service on 0800 111 999, then ring us to trace and repair.
A previous engineer had reported a leak on the safety check. We found it at the condensate collector, whose seals had perished. Everything came out of the combustion box to replace it, and the boiler went back together burning cleanly.
Several engineers and a shower pump had not fixed it. The gate valve on the vented cylinder had snapped inside, turning freely but barely open. A full-bore lever valve in its place, and the tenants had proper hot water pressure for the first time in over a year.
The old cylinder was leaking through the ceiling below. We quoted a replacement, the customer accepted, and a new 150-litre stainless unvented cylinder went in to current standards with the pipework insulated. G3 work, done by G3 engineers.