24 hour emergency call-out07413 385767
Answered 7 days a week, day or night
Case study · Gas fires · Stourbridge
Stourbridge: a gas fire fitted in front of an old back boiler, and a second fire in a room used for sleeping
The son of an elderly customer in Stourbridge booked us to service her gas fires and her boiler. Behind the fire in the rear room, the old back boiler unit had never been removed, and the fire should not have been fitted like that. The front room is used for sleeping, so the fire there is At Risk. The Vaillant ecoTEC pro 28 boiler was serviced and working perfectly.
The son of an elderly customer in Stourbridge booked a service of her two gas fires and her boiler. In the rear room we serviced the fire and found the old back boiler unit still behind it: it had never been removed, and the fire should not have been fitted like that. The fire passed its flue flow and spillage tests, but with the customer's permission we turned it off and it is labelled not to use. The front room is used for sleeping. Using a gas fire in a room you sleep in is At Risk, so we advised the customer to turn that fire off and not use it. The Vaillant ecoTEC pro 28 boiler was serviced and is working perfectly; we walked the heating system and bled the radiators.
Request an engineer
Four details and we will get back to you to arrange a time. Prefer to talk? Call 07413 385767.
£99 in office hours (Mon–Fri, 8am–5pm) covers attendance, diagnosis and the first hour. Parts and any further work are quoted and agreed before we carry on. Out of hours, the price is quoted by phone before we set off.
No travel charge within 10 miles of B20 2JS. Further out, £2 per mile may apply — always agreed before anything is booked. Full price list
Smell gas now? Do not use this form or wait for a reply. Call the National Gas Emergency Service free on 0800 111 999 (24 hours). If you are using a mobile, make the call from outside. Open doors and windows, do not switch electrics on or off, do not smoke or use naked flames, and turn the gas off at the meter if it is safe to do so, unless the meter is in a cellar or basement. Once the supply has been made safe, we can trace and repair the fault.
Rear-room fireOld back boiler left behind it; turned off
Front-room fireRoom used for sleeping: At Risk
BoilerVaillant ecoTEC pro 28 serviced, working perfectly
The rear-room fireThe gas fire in the rear room, before we took the case off.Cadent’s labelCadent, the gas emergency service, had attended before us. This Do Not Use label is theirs.Case offThe fire with its case off, during the service.Back boiler still thereBehind the fire: the old back boiler unit had never been removed.Gas supply and debrisThe gas supply to the fire, at the base of the opening, with debris around it.The front-room fireThe fire in the front room, which is used for sleeping. We advised the customer to turn it off and not use it.
The booking
The son of an elderly customer in Stourbridge booked us to service her gas fires and her boiler at the same visit.
The fire in the rear room
We started in the rear room. Cadent, the gas emergency service, had attended before us, and the Do Not Use label on top of this fire is theirs.
We serviced the fire. With the case off, we found that the old back boiler unit behind it had never been removed. It was still sitting in the fireplace opening, with rubble and debris around it and beside the gas supply to the fire. We confirmed that the fire should not have been fitted like that.
The fire did pass its flue flow and spillage tests. Even so, with the customer's permission, we turned it off, and it is labelled not to use.
The fire in the front room
The front room is used for sleeping. Using a gas fire in a room you sleep in is At Risk, so we advised the customer to turn the front-room fire off and not to use it.
Gas Safe Technical Bulletin 055 confirms that a non-compliant open-flued appliance in sleeping accommodation should be classed At Risk (AR), including where the room is only used for sleeping temporarily.
The boiler
We serviced the Vaillant ecoTEC pro 28 boiler, and it was all working perfectly. We also walked the heating system and bled the radiators.
What At Risk means
At Risk is a classification under the Gas Industry Unsafe Situations Procedure. The appliance is not dangerous at that moment, but there is a fault or situation that could make it dangerous. The engineer explains the risk and, with the customer's permission, turns the appliance off. It should stay off until the problem has been put right.
If an old fire is no longer wanted, we remove it and cap the supply for £120, tested and documented. More about servicing and removing fires is on our gas fires page.
What it costs
A gas fire service is £120. When it is booked with a boiler service at the same visit, it is £100 per fire, for up to two fires. A basic boiler service is £95. Details are on our price list.
Common questions
Can I use a gas fire in a room I sleep in?
Not without having it checked first. Gas Safe Technical Bulletin 055 says that a non-compliant open-flued appliance in a room used for sleeping should be classed At Risk, including where the room is only used for sleeping temporarily. If a room with a gas fire has become a bedroom, ask a Gas Safe engineer to look at it before the fire is used again.
What is a back boiler?
A back boiler is an older type of boiler that sits in the fireplace opening, behind a gas fire. When one is taken out of use, the old unit should be removed. On this job it had been left in the opening, and a fire had been fitted in front of it.
The fire passed its tests, so why was it turned off?
Flue flow and spillage tests show how a fire is performing on the day of the test. They do not make an installation right that should not have been done. With the customer’s permission, we turned the fire off rather than leave it in use.
What does At Risk mean?
At Risk is a classification under the Gas Industry Unsafe Situations Procedure. It means the appliance is not dangerous at that moment, but there is a fault or situation that could make it dangerous. The engineer explains the risk and, with the customer’s permission, turns the appliance off. It should stay off until the problem has been put right.
How much does a gas fire service cost?
A gas fire service is £120. If it is booked with a boiler service at the same visit, it is £100 per fire, for up to two fires. A basic boiler service is £95.
Job attended and photographed by our engineers, November 2026. Written up by Saeed Iqbal, the engineer who leads Synergy Gas & Plumbing (Gas Safe registered 594385). More of our work in the area is on our Stourbridge page, and every job we write up is on the case studies index.
What it costs
Updated Sept 2026
£120 gas fire service
A gas fire service is £120, or £100 per fire (up to two fires) when it is booked with a boiler service at the same visit. A basic boiler service is £95.
No travel charge within 10 miles of B20 2JS. Further out, £2 per mile may apply — always agreed before anything is booked.
Not in the best of condition: a damaged baffle, a worn burner gasket and an extremely noisy fan. Gasket replaced, minimum-rate CO2 adjusted from 7.4% to 9.0%, and a quote left for the rest.
A routine annual service: condensate trap and magnetic filter cleaned, clean combustion readings. Following the flue into the loft, we found it held only by metal banding with the joint clamps unscrewed. Warning notice left, quote accepted, return visit booked.
A returning customer's Worcester CDi was showing EA with no hot water. After completing our safety checks we traced it to the gas valve. We ordered it, came back, fitted it and checked the boiler again before signing off.