Boiler Fault Codes Explained: Vaillant, Worcester, Baxi, Ideal & Glow-worm

Fault codes differ by manufacturer, but the same handful of problems show up again and again: low pressure, a flame that won't light or won't stay lit, a frozen condensat…

Quick answer

Fault codes differ by manufacturer, but the same handful of problems show up again and again: low pressure, a flame that won't light or won't stay lit, a frozen condensate pipe, and a fan or sensor fault. Low pressure and an accessible frozen condensate pipe are the only two things worth trying yourself. Anything involving ignition, the gas valve, the flue or a repeating fault code needs a Gas Safe registered engineer.

Before you look up the code

Two checks solve a large share of callouts, whatever make of boiler you have.

  • Pressure. Look at the gauge. Below 1 bar cold, top up via the filling loop to about 1.2–1.5 bar.
  • Frozen condensate pipe. In cold weather, the white plastic pipe running outside can freeze and lock the boiler out. Pour warm — never boiling — water along it, then reset once.

If either fixes it, you're done. If the same code comes straight back, stop resetting and book an engineer — repeated resets on a genuine fault can wear ignition components faster and, on some faults, aren't safe to keep repeating.

These sections cover the fault codes we're asked about most often, cross-checked against manufacturer documentation and current engineer guidance. They're a starting point for understanding what your boiler is telling you, not a substitute for the fault-code sticker inside your own boiler's casing flap — always check that against your exact model, since the same code can mean something different on an older or newer range from the same manufacturer.

Vaillant fault codes

Vaillant (ecoTEC, ecoFIT, turboTEC) uses F-prefixed codes, shown as "F." followed by two digits.

CodeWhat it meansSafe to try yourself?
F.22System water pressure too lowYes — repressurise via the filling loop
F.28Ignition failure — boiler tried to light and couldn'tNo — check gas supply and condensate pipe, then one reset only
F.29Flame lit successfully, then lost during operationNo — engineer diagnosis needed
F.75Pump or pressure sensor fault — boiler can't detect water movementNo — usually a stuck pump or faulty sensor

Worcester Bosch fault codes

Worcester Bosch Greenstar models show a fault code paired with a cause code — for example "EA" with "227" — and it's the pair together that identifies the problem.

CodeWhat it meansSafe to try yourself?
EA 227No flame detected after ignitionOften a frozen condensate pipe — thaw and reset once
EA 229Flame was lit, then lost during operationNo — engineer diagnosis needed
E9 224Flue or high-limit thermostat activated (overheat)No — flue and fan need inspecting
A1 281Pump stuck or running dryNo — check pressure first, then engineer

Baxi fault codes

Baxi (Duo-tec, Platinum+, Megaflo System) uses three-digit E-codes. The exact set varies a little by range, so check the label inside the casing flap for your specific model.

CodeWhat it meansSafe to try yourself?
E119Low system water pressureYes — repressurise via the filling loop
E133Ignition or gas supply faultCheck gas supply and condensate pipe, then one reset
E125Circulation fault — poor water movement round the systemNo — often pump, airlock or blockage
E168General fault, often after a power interruptionWorth one reset — call an engineer if it returns

Ideal fault codes

Ideal (Logic, Logic+, Vogue) mixes F- and L-prefixed codes depending on the model and control board fitted.

CodeWhat it meansSafe to try yourself?
F1Low system water pressureYes — repressurise via the filling loop
L2 / F2Ignition lockout — flame lost or never establishedCheck gas supply and condensate pipe, then one reset
F3Fan faultNo — engineer diagnosis needed
L9 / F9PCB (control board) faultNo — engineer diagnosis needed
L5Five or more resets within about 15 minutes — a safety trip, not a new faultNo — find and fix what's actually triggering it (usually F1 or L2)

Glow-worm fault codes

Glow-worm (part of the Vaillant Group) is the one manufacturer here where we'd urge real caution reading a generic table: fault codes vary more between its own ranges — Betacom, Flexicom, Ultracom — than they do for the other four manufacturers above. Betacom models don't show a code at all, just a coloured LED. The two codes below are consistent across most current ranges; for anything else, check your model's own label or manual rather than a general guide.

CodeWhat it meansSafe to try yourself?
F22Low system water pressureYes — repressurise via the filling loop
F28Ignition fault, commonly a frozen condensate pipeCheck condensate pipe, thaw if frozen, then one reset

When a code means stop, don't reset

  • Any smell of gas — turn off at the meter, ventilate, leave, call 0800 111 999
  • A code that returns straight after a reset
  • Scorching, soot, or a carbon monoxide alarm sounding
  • Water visibly leaking from the boiler itself

None of these are DIY territory, whatever the code says. Turn the boiler off and call us.

Rather we rang you?

Leave a number and a postcode. We will call you back — usually within the hour during office hours.

Written by the engineering team at Synergy Gas & Plumbing, Gas Safe registered 594385. Last reviewed August 2026.

Get a price

Four taps for a fixed figure.

What do you need?

What sort of job is it?

Here is the price range

We use your number to quote this job and nothing else. No marketing lists.

Call us — do not wait on a form

07413 385767 Answered 24 hours. If you can smell gas, first call the National Gas Emergency Service on 0800 111 999, then ring us to trace and repair.
Call now

Sent — thanks.

We answer enquiries the same working day. If it cannot wait, ring 07413 385767.

Pick a slot online instead

Need an engineer?

Birmingham
Repair callout£99
Annual service£95
Landlord CP12£90
Emergency24/7
Answers

Common questions

Can I fix a boiler fault code myself?

Only two things are genuinely safe to try: repressurising via the filling loop if the code points to low pressure, and thawing an accessible external condensate pipe with warm water if it's frozen. Everything else — ignition, gas valve, flue, fan, sensors, PCB — needs a Gas Safe registered engineer.

Is it safe to keep resetting my boiler?

One reset after checking pressure and the condensate pipe is reasonable. If the same code comes straight back, stop. Repeated resets on a genuine fault can wear ignition components out faster and, with some faults, aren't safe to keep repeating.

Why do fault codes differ between manufacturers?

Each manufacturer designs its own control board and diagnostic logic, so there's no universal standard — F22 means something different on a Vaillant than a Glow-worm, for instance, even though the two brands are related. Always check against your specific model.

My fault code isn't listed here — what do I do?

This guide covers the fault codes we're asked about most, not every code that exists. Check the sticker inside your boiler's casing flap or your user manual for the full list for your exact model, or call us with the code and we can usually tell you what it means over the phone.

Boiler playing up? We can usually get to you the same day.

Call the Birmingham office for a straight answer and a fixed price before we start work.

Call07413 385767 WhatsAppSend a photo BookPick a slot
WhatsApp us